go to text

Management of Flare Pipes

① Set the specified torque with a constant torque wrench, lock and tighten.
② Keep the inside of the flare nut and flare pipe dust-proof to prevent foreign matter and dust from entering.
③ Lightly hand-tighten the flare nut and flare pipe, and tighten them with a constant torque wrench until they click.Fix one end with a spanner.
④ Assemble the flare pipe Comp so that it does not deform during installation.
(Do not force the assembly. Temporarily tighten both ends and then fully tighten one.)
Points to note: (1) There should be no line misalignment with the mating part.
(2) The control point is the tightening torque.
 
                        combination material

Applicable tube
Flare type
Iron
Non-ferrous
4.76
13~18{133~184}
6~11{61~112}
6.35
16~23{163~235}
8~15{82~153}
8
29~39{296~398}
20~29{204~290}
10
39~49{398~500}
27~39{275~398}
12/12.7
59~78{602~795}
44~59{449~602}
15
69~93{704~948}
51~69{520~704}
N・m{kgf・cm}
 
table.Tightening torque (Refer to JASO F 402-90 commentary)